Hi, I'm Tom. Welcome to our shop,
Carymart offers you the premium rf remote control equipment.
We suggest you reading our FAQs before making your decision.
If you have any other question, please contact us.
We will reply you as soon as possible.
Package Include:
1 x Receiver: S1X-DC12-ANT3 / S1X-DC24-ANT3
2 x Remote: C-2
1 x Electric solenoid valve
1 x Power adapter: DC12V/3A or DC24V/3A
1 x User manual
Application:
It may be
used in all types of industry automation, agriculture, business, home,
factory, house, farm, garage, vehicle, ship, aerial vehicle, etc. It can
remote control different DC equipment on land, water, and air, such as
lights, doors, windows, lamps, sockets, locks, sirens, outlets, heaters,
motors, fans, winches, curtains, blinds, linear actuators, electric solenoid
valves, and security alarm systems. The applications are endless.
Feature:
Wireless control, easy to install.
Waterproof: The receiver has waterproof case and waterproof connector, it
can be installed outdoors.
It can control DC equipment with voltage12V / 24V.
With external antenna, the receiver has a farther working range.
The transmitter / remote can control the receiver from any place within a
reliable working distance.
Wireless RF signal from the transmitter can pass through walls, floors,
doors, or windows, but it will lose some operating range.
The receiver has reverse voltage protection and overcurrent protection.
The receiver can only be triggered by paired transmitters.
One or more transmitters / remotes can control one or several receivers
simultaneously.
Two or more receivers may be used in the same area.
Receiver Parameters:
Model: S1X-DC12-ANT3 / S1X-DC24-ANT3
Operating Voltage: 12±1VDC (model S1X-DC12-ANT3), or 24±2VDC (model
S1X-DC24-ANT3), the operating voltage
must be specified when ordering.
Working Frequency: 433.92 MHz
Quiescent Current: ≤6mA
Channel: 1 CH
Output Type: 12±1VDC (S1X-DC12-ANT3) or 24±1VDC (S1X-DC24-ANT3)
Maximum Load Current of Relay: 10A / channel
Suitable Wires for Connecting Terminals: 22-12 AWG
3 Selectable Working Modes: Self-locking, Momentary, Interlocking
Operating Temperature: -20 °C ~ +70 °C
PCB size: 88 x 80 x 18 mm (3.5 x 3.1 x 0.7 inches)
Case size: 115 x 90 x 55 mm (4.5 x 3.6 x 2.2 inches)
Transmitter Parameters:
Model: 0021001 (C-2)
Channel/Button: 2
Button Symbol:1, 2
Operating Voltage: 12V (1 x 23A -12V battery, can be used for 12 months)
Operating Current: 6mA
Operating Frequency: 433Mhz
Encoding Chip: PT2262/ PT2264/ SC2262
Transmitting Distance: 100m / 300ft (theoretically)
Modulation Mode: ASK
Operating Temperature: -20 ° C to +70 ° C
Unit Size: 58 x 39 x 16 mm
Electric Solenoid Valve Parameters:
Wattage: 24W
Working Voltage: DC12V / DC24V
Type: normally closed (power on, solenoid valve open; power off, solenoid
valve close)
Working Temperature: -5℃~100℃
Operating Pressure: 0~1.0Mpa (0~10kg/cm²)
Material of valve body and coil: 100% Brass
Usage: water, air, diesel, gas, low viscosity fluids
Pipe sized
1/8"
1/4"
3/8"
1/2"
3/4"
1"
1.2"
1.5"
2"
Thread type
G1/8"
G1/4"
G3/8"
G1/2"
G3/4"
G1"
G1.2"
G1.5"
G2"
Internal Orifice
9MM
12MM
15MM
20MM
25MM
32MM
40MM
45MM
58MM
Usage:
Setting different control modes:
The receiver will be set in Self-locking mode before leaving the factory, if
you want to use another mode, please follow the following steps.
1) Setting Momentary mode: Press the learning button in the receiver 2
times, signal LED continuously flashes 2 times and then goes off.
The operation of Momentary mode with the transmitter:
Press and hold the button A on the transmitter: The terminal <OUT1> of the
receiver outputs DC power, and the electric solenoid valve work.
Release the buttonA: The terminal <OUT1> of the receiver stops outputting,
and the electric solenoid valve stops work.
2) Setting Self-locking mode: Press the learning button in the receiver 3
times, signal LED continuously flashes 3 times and then goes off.
The operation of Self-locking mode with the transmitter:
Press the button A on the transmitter: The terminal <OUT1> of the receiver
outputs DC power, and the electric solenoid valve work.
Press the button A again: The terminal <OUT1> of the receiver stops
outputting, and the electric solenoid valve stops work.
3) Setting Interlocking mode: Press the learning button in the receiver 4
times, signal LED continuously flashes 4 times and then goes off.
The operation of Interlocking mode with the transmitter:
Press the button A on the transmitter: The terminal <OUT1> of the receiver
outputs DC power, and the electric solenoid valve work.
Press the button B on the transmitter: The terminal <OUT1> of the receiver
stops outputting, and the electric solenoid valve stops work.
How to pair the transmitter to the receiver:
Notice: We have paired the transmitter to the receiver before leaving the
factory.
1) Press the learning button once in the receiver, signal LED on the
receiver flashes one time and then stays on, this indicates that the
receiver enters the learning status.
2) Press button A on transmitter, if the signal LED
flashes one time, this indicates that the pairing with button A is
successful. Then press button B on transmitter, if the signal LED flashes
one time, this indicates that the pairing with button B is successful.
3) Press the learning button in the receiver again for 1-2 seconds, signal
LED turns off, this indicates that the receiver exits the learning status.
4) The receiver can learn several transmitters with different codes.
How to delete all transmitters codes stored in the receiver:
Notice: We have paired the transmitter to the receiver, if you don’t want
the receiver to work with the transmitter, you can delete all transmitters
codes stored in the receiver.
Operation: Press the learning button in the receiver 10 times and then
release the learning button, signal LED flashes 10 times quickly and then
goes off, this indicates that all stored codes have been deleted
successfully.