1. How to connect the equipments to the DC receiver -relay output type It can control ON / OFF of AC equipments or DC equipments.The connection method is applicable to the following receivers: S1T-DC12, S1M-DC12, S1L-DC12, S1U-DC12, S1RU-DC12, S1D-DC12, S1UD-DC12, S1US-DC12, S1DA-DC12, S1UA-DC12, S1UW-DC12 S2T-DC12, S2M-DC12, S2L-DC12, S2U-DC12, S2UA-DC12, S2UW-DC12, S2DA-DC12, S2PDA-DC12, S1UB-DC12, S2UB-DC12, S4UB-DC12 S4C-DC12, S4T-DC12, S4M-DC12, S4U-DC12, S6C-DC12, S8CA-DC12, S12CA-DC12, S15C-DC12, S16C-DC12 S1PU-DC12, S2PU-DC12, S4PU-DC12, S1PDA-DC12, S1PUB-DC12, S2PUB-DC12,S1PUW-DC12, S2PUW-DC12, S4PUW-DC12 Operation: 1) If you want to control DC equipment, do as following: a. Connect the positive pole of DC power supply to terminal “L / +” of INPUT, and connect the negative pole of DC power supply to terminal “N / -” of INPUT. b. Connect “normally open terminal” of receiver to the positive pole of DC power supply, connect “Common terminal” of receiver to the positive pole of DC equipment, and connect the negative pole of DC equipment to the negative pole of DC power supply.
2) If you want to control AC equipment, do as following: a. Connect the positive pole of DC power supply to terminal “L / +” of INPUT, and connect the negative pole of DC power supply to terminal “N / -” of INPUT. b. Connect “normally open terminal” of receiver to the live wire of AC power supply, connect terminal “Common terminal” of receiver to one side of AC equipment, and connect another side of AC equipment to the neutral wire of AC power supply.
2. How to connect the equipments to the AC receiver -relay output type It can control ON / OFF of AC equipments or DC equipments.The connection method is applicable to the following receivers: S1U-AC220, S1MU-AC220, S1UB-AC220, S1PU-AC220, S1PT-AC220, S1PUB-AC220, S1PUW-AC220, S1DA-AC220, S1PDA-AC220, S1UW-AC220 S2U-AC220, S2MU-AC220, S2UB-AC220, S2UW-AC220, S2PU-AC220, S2PUB-AC220, S2PUW-AC220, S2DA-AC220 S2PDA-AC220, S6C-AC220, S4U-AC220, S4MU-AC220, S4UB-AC220, S4PU-AC220, S4PUW-AC220 Operation: 1) If you want to control DC equipment, do as following: a. Connect the live wire of AC power supply to terminal “L / +” of INPUT, and connect the neutral wire of AC power supply to terminal “N / -” of INPUT. b. Connect “normally open terminal” of receiver to the positive pole of DC power supply, connect “Common terminal” of receiver to the positive pole of DC equipment, and connect the negative pole of DC equipment to the negative pole of DC power supply.
2) If you want to control AC equipment, do as following: a. Connect the live wire of AC power supply to terminal “L / +” of INPUT, and connect the neutral wire of AC power supply to terminal “N / -” of INPUT. b. Connect “normally open terminal” of receiver to the live wire of AC power supply, connect terminal “Common terminal” of receiver to one side of AC equipment, and connect another side of AC equipment to the neutral wire of AC power supply.
|