Hi, I'm Tom. Welcome to our shop,
Carymart offers you the premium rf remote control equipment.
We suggest you reading our FAQs before making your decision.
If you have any other question, please contact us.
We will reply you as soon as possible.
Introduction:
If you want to use multiple linear actuators to raise and lower an
equipment, for example two, three or four electric actuators. Since the
high-speed DC motors in electric actuators cannot run at exactly the same
speed, so the movement speed of the electric actuator will also be
different. When multiple electric actuators work at the same time, their
actual speeds cannot be exactly the same. In this case, we can use a
synchronous controller to operate multiple linear actuators to rise or fall
synchronously. They work completely in sync without any difference.
Working principle:
If you want to use a synchronous controller to operate 2, 3 or 4 linear
actuators fully synchronously, you will need to add built-in Hall effect
sensors to each linear actuator. And when you purchased Hall effect sensor
along with linear actuator, we will install Hall effect sensor to linear
actuator for you.
When 2, 3 or 4 linear actuators are running together, Hall sensor will send
Hall signals to the synchronization controller, and the controller will
adjust the running speed of each linear actuator, so that all linear
actuators run at the exact same speed.
Feature:
It can operate three
electric linear actuators A
to run completely
synchronously.
Wired control via a touch control handle.
Wireless control via a remote.
If use an external antenna, the controller has a farther working range.
The LED display on the control handle will display the stroke position in
real time.
Six touch function buttons: ▲, ▼, 1, 2, 3 and R.
Buttons ▲ and ▼ are used to operate the linear actuators extension and
retraction.
Buttons 1, 2 and 3 are used to automatically operate the linear actuators to
three pre-memorized positions.
Button R is the reset button and is used to reset the system in case of an
error.
With wired control terminals: You can connect manual switches to control
linear actuators.
With reset button.
When linear actuators move close to the end position, they will
automatically slow down to protect themselves.
When linear actuators are fully retracted, they will retain 1MM of travel to
protect themselves.
Parameters:
Working Voltage: 12~36 VDC, suitable for 12V or 24V linear actuator
Number of connecting linear actuators: 3
Maximum output current: 10A / channel
Working Frequency: 433.92 MHz
Two selectable control modes: Interlocking mode or Momentary mode, please
select a control mode you need when ordering.
Working Distance: 30m / 90ft (theoretically)
Case size: 158 x 150 x 40 mm (6.2 x 5.9 x 1.6 inches)
Operating Temperature: -20°C ~ +70°C
Connection:
1) Plug the touch control handle into the port Hand Set of the controller.
2) Plug three linear actuators into the ports CH1, CH2 and CH3 of the
controller.
3) Connect the positive pole of DC power supply to the terminal + of the
controller, and connect the negative pole of DC power supply to the terminal
- of the controller. CAUTION: Do not connect AC power directly to the controller!
Operation:
1. Operation via the touch control handle:
Attention: The handle is operated by touch control. The touch sensitivity
can be automatically calibrated when powered on for the first time. Hands
are prohibited from touching the handle when powered on to prevent
interference with the sensitivity calibration and affect the operating
sensitivity.
1) Press and hold the ▲ button of the control handle, three linear actuators
extend outward at the same time; Release the button, three linear actuators
stop at the same time.
2) Press and hold the ▼ button of the control handle, three linear actuators
retract inward at the same time; Release the button, three linear actuators
stop at the same time.
3) Press any of the button 1, 2, or 3 on the control handle, three linear
actuators will automatically move to the position memorized by that button
and then automatically stop.
Note: You will need to first memorize three positions into these three
buttons.
4) The LED display on the control handle will display the stroke position
data in real time. For example, the number 03.5 means that the linear
actuators have reached the stroke position of 35MM.
2. Operation via the remote control: (The remote control of the synchronous
controller has two control modes, interlocking mode and momentary mode,
please select a control mode you need when ordering.) 2.1 Momentary Control Mode:
1) Press and hold the button ▲ of the remote control, three linear actuators
extend out at the same time; Release the button, three linear actuators stop
at the same time.
2) Press and hold the button ▼ of the remote control, three linear actuators
retract inward at the same time; Release the button, three linear actuators
stop at the same time.
2.2 Interlocking Control Mode:
1) Press the button ▲ of the remote control, three linear actuators extend
out at the same time, they will reach the maximum stroke at the same time
and stop automatically. During operation, you can also press any button of
the remote control to stop three linear actuators at the same time.
2) Press the button ▼ of the remote control, three linear actuators retract
inward at the same time, they will fully retract at the same time and stop
automatically. During operation, you can also press any button of the remote
control to stop three linear actuators at the same time.
3. Operation via the manual switch:
The controller has wired control terminals, and you can connect external
devices (with normally open contact), such as manual switches to wired
control terminals, then use them to control linear actuators.
For example, you can connect two manual switches to wired control terminals
UP and DOWN according to following wiring diagram. The operation:
1) Press the UP button of the manual switch, three linear actuators extend
outward at the same time. During operation, you can also press any button of
two manual switches to stop three linear actuators at the same time.
2) Press the DOWN button of the manual switch, three linear actuators
retract inward at the same time. During operation, you can also press any
button of two manual switches to stop three linear actuators at the same
time.
How to memorize three stroke positions:
1) The controller can memorize total three stroke positions, and each button
memorizes one stroke position.
2) First operate three linear actuators to the first suitable stroke
position that you need to store, then press and hold the button 1 of the
control handle for about 5 seconds, the stroke value on the LED display will
flash. This means that the current stroke position is already stored in
button 1.
3) You can continue to store the other two stroke positions into the button
2 and 3 by following the operation above.
Reset Function:
When the LED display on the control handle shows the fault code, you need to
reset the system as follows.
Reset operation: Press and hold the R button of the control handle or
press and hold the Reset button on the controller, or press and hold the ▲
and ▼ buttons on the remote control at the same time, until all linear
actuators are reset to the bottom, and the LED display on the control handle
shows "00.1", then release the button.
How to pair the remote control to the controller:
Notice: We have paired the transmitter to the controller before leaving the
factory.
1) Press and hold the pairing button on the controller for 8-9 seconds, the
signal LED on the receiver board turns on, this indicates that the
controller enters the learning status.
2) Press any one button on the transmitter, if signal LED on the receiver
board flashes 2 times and then goes off, this indicates that the pairing is
successful.
3) The controller can learn several transmitters with different codes.
How to delete the remote control:
We have paired the transmitter to the controller, if you don’t want the
controller to work with the transmitter, you can delete all transmitters
codes stored in the controller.
Operation: Quickly and continuously press the learning button on the
receiver board 8 times, then release the learning button, the signal LED on
the receiver board flashes 8 times and then goes off, this indicates that
all stored codes have been deleted successfully.
Package Include:
1 x Synchronous Controller (One-Control-Three, For 3 Linear Actuators A with
Hall effect sensors)
1 x Touch Control Handle
1 x Remote Control
1 x User manual
Note: Three linear actuators A are not included,
please order them separately. The remote control of the synchronous
controller has two control modes, interlocking mode and momentary mode,
please select a control mode you need when ordering.